Product Display
Product size
Product exploded view
Basic electrical parameters
Description | Condition | Minimum | typical | maximum | unit |
power | a) Test voltage: control voltage: DC24V; load voltage: 600VDC b) ambient temperature: 20℃±2℃; water inlet temperature: 0℃±2℃; flow rate: 10L/min |
8000 |
W | ||
weight | No coolant, no connecting wire | 2.7 | KG | ||
Antifreeze volume | 170 | mL |
Temperature
Description | Condition | Minimum | typical | maximum | unit |
Storage temperature | -40 | 105 | ℃ | ||
Working temperature | -40 | 105 | ℃ | ||
environment humidity | 5% | 95% | RH |
Low pressure
Description | Condition | Minimum | typical | maximum | unit |
Control voltage VCC | 18 | 24 | 32 | V | |
Ground | 0 | V | |||
Supply current | Steady state current | 90 | 120 | 160 | mA |
Starting current | 1 | A |
High pressure
Description | Condition | Minimum | typical | maximum | unit |
Supply voltage | Turn on heating | 480 | 600 | 720 | V |
Supply current | Nominal condition | 13.3 | A | ||
Inrush current | Nominal condition | 17.3 | A | ||
stand-by current | Nominal condition | 1.6 | mA |
High voltage safety
1 | High voltage warning label | have |
2 | Flame-retardant plastic insulation shell protection to prevent access to high-voltage live parts | have |
3 | Basic insulation of high voltage live parts | have |
4 | Provide potential equalization grounding point | have |
5 | Insulation resistance>50MÙ | have |
6 | Passive discharge | have |
7 | High voltage interlock | have |
8 | High voltage terminals comply with IPXXB protection | have |
9 | Meets IP67 protection | have |
10 | Comply with 2U+1000V withstand voltage test | have |
11 | High pressure and overpressure turn off heating | have |
12 | PTC over temperature protection | have |
13 | PCB over temperature protection | have |
14 | IGBT over temperature protection | have |
15 | PTC overcurrent protection | have |
16 | PTC short circuit protection | have |
17 | IGBT breakdown feedback | have |
18 | PTC temperature sensor failure detection, no heating when failure | have |
19 | IGBT temperature sensor failure detection, no heating when failure | have |
20 | PCB temperature sensor failure detection, no heating when failure | have |
21 | Even if the IGBT control fails, the heater temperature does not exceed 200+℃ due to PTC's own characteristics | have |
22 | Low voltage anti-reverse connection | have |
23 | High voltage reverse connection feedback (reverse connection will cause uncontrolled heating and cause PTC damage) | have |
24 | Controller power on and self-check, no heating if there is a fault | have |
25 | Communication is interrupted and heating is stopped | have |
26 | High voltage acquisition real-time feedback | have |